| |
- 开机(power on)
- SETUP(出现1234)
- ENTER(出现0000为密码正确;出现E000则为密码错误,此时先按ENTER,再将密码设置成通用密码8888,再按RESET,重复第2步操作)
- 再按一次ENTER,出现d001(表示报警时长为1)
- 按SELECT,出现10XX(1表示第1区,XX表示此区灵敏度数值)此时可以开始设置各区灵敏度,按SETUP切换不同区,按SELECT改变十位的数值,按ENTER改变个位数值;1至6区位的数值越高,则其灵敏度越高;第7区代表整台门的总体灵敏度,数值越低其总体灵敏度越高;第8区为门的总体稳定性调节,设置成000为宜。
- 设置完毕后按RESET键结束操作。
DEBUGGING OF STAR LEGEND SERIAL
GG-III WALK THROUGH METAL DETECTOR
- POWER ON
- SETUP (Showing ”1234”)
- ENTER (Showing ”0000” means Password Correct; Showing ”E000” means Password incorrect, press ENTER, and change password to a common one “8888”, then press RESET, and return to the second step)
- Press ENTER, showing ”d001” (means alarm time is 1)
- Press SELECT, showing ”10XX” (Here ”1” refers to the first zone, ”XX” refers to the sensitivity), here we can begin to set the sensitivity, press SETUP to switch between different zones, press SELECT to change the tens digit and press ENTER to change the units digit; the larger digital zone 1 to zone 6 shows, the higher sensitivity you get; zone 7 refers to the sensitivity of the whole check gate, the larger digital in zone 7, the lower sensitivity you get; zone 8 refers to the stability of the whole gate, best to set to ”000”.
- Finally press RESET to finish debugging.
星河传说系列GG-LED安检门使用及调试方法
1. 开机(power on)
- SETUP(出现1234)
- ENTER(出现0000为密码正确;出现E000则为密码错误,此时先按ENTER,再将密码设置成通用密码8888,再按RESET,重复第2步操作)
- 再按一次ENTER,出现d001(表示报警时长为1)
- 按SETUP,出现10XX(1表示第1区,XX表示此区灵敏度数值)此时可以开始设置各区灵敏度,按SETUP切换不同区,按SELECT改变十位的数值,按ENTER改变个位数值;1至6区位的数值越高,则其灵敏度越高;第7区代表整台门的总体灵敏度,数值越低其总体灵敏度越高;第8区为门的总体稳定性调节,设置成000为宜。
- 设置完毕后按RESET键结束操作。
DEBUGGING OF STAR LEGNED SERIAL GG-LED WALK THROUGH METAL DETECTOR
- POWER ON
- SETUP (Showing ”1234”)
- ENTER (Showing ”0000” means password correct; Showing ”E000” means password incorrect, press ENTER and set the password to the common one ”8888”, then press RESET and go back to the second step)
- Press ENTER, showing ”d001”, it means alarm time is 1.
- Press SETUP, showing ”10XX” (Here ”1” refers to zone 1, ”XX” refers to the sensitivity of this zone), then you can begin to set the sensitivity of different zones. Press SETUP to switch between zones, press SELECT to change the tens digit and press ENTER to change the units digit; the larger digital zone 1 to zone 6 shows, the higher sensitivity you get; zone 7 refers to the sensitivity of the whole check gate, the larger digital in zone 7, the lower sensitivity you get; zone 8 refers to the stability of the whole gate, best to set to ”000”.
- Finally press RESET to finish debugging.
附:常用灵敏度设置 (Most common used settings)
1. 高灵敏度, 工厂设置(可准确探测一枚一元硬币)High Sensitivity, Use in Factory(can detect a coin)
1095
2099
3099
4099
5099
6080
7010
8000
2. 低灵敏度, 娱乐场所设置(可排除手机,钥匙等小件物品)Low Sensitivity, Use in Court(can exclude keys, mobiles)
1005
2010
3010
4010
5010
6005
7099
8000
|